9132-50   CLAMP ON PROBE
"Å« Àü·ùÃøÁ¤À» À§ÇÑ ·¹ÄÚ´õ¿Í °£´ÜÈ÷ Á¢¼Ó "
 
       
 
6°³ÀÇ ·¹ÀÎÁö ¼±Åð¡´É
°íÁ¶ÆÄ ½ÅÈ£ÀÇ Á¤È®ÇÑ ÆÄÇüÀ» ºÐ¼®ÇÏ°Å ·¹ÄÚµùÀ§ÇØ ÇÊ¿ä
 
Basic specifications
9132-50 9010-50
Rated current AC 20/50/100/200/500/1000 A AC 10/20/50/100/200/500 A
Accuracy ¡¾3% rdg. ¡¾0.2% f.s. (45 to 66Hz) ¡¾2% rdg. ¡¾1% f.s. (45 to 66Hz)
Frequency characteristics Add to amplitude accuracy for frequencies from 40 to 1kHz: ¡¾ 1% rdg. Add to amplitude accuracy for frequencies from 40 to 1kHz: ¡¾6% rdg. (at 10A and 20A range)
¡¾3% rdg. (for 50A range and above)
Output rate 0.2V AC f.s. (f.s.=setting rage)
(Connect to a voltage input device providing a high input impedance of 1M§Ù)
Max. current input (For 40Hz to500 Hz: 100%, and for 500Hz to 1kHz: within 90% of derating)
1000Arms continuous (all ranges)
(For 40Hz to 100Hz: 100%, and for 100Hz to 1kHz: within 50% of derating)
150Arms continuous (10/20/50A ranges)
400Arms continuous (100/200A ranges)
650Arms continuous (500A range)
Max. circuit voltage 600Vrms (Insulated conductor) 600Vrms (Insulated conductor)
Diameter ¨ª 55mm(2.17in), or 20mm(0.79in) ¡¿ 80mm(3.15in) busbar ¨ª 46mm(1.81in)
Dimensions, mass 100mm(3.94in)W ¡¿ 224mm(8.82in)H ¡¿ 35mm(1.38in)D, 600g(21.2oz), cord length: 3m(9.84ft) 78mm(3.07in)W ¡¿ 188mm(7.40in)H ¡¿ 35mm(1.38in)D, 420g(14.8oz), cord length: 3m(9.84ft)