CT6846
AC/DC CURRENT PROBE
|
|
"³ÐÀº ¿Âµµ ¹üÀ§¿¡¼ ´ëÀü·ùÀÇ °íÁ¤È®µµ ÃøÁ¤À» ±¸Çö"
|
|
|
|
|
|
|
|
|
|
|
|
|
| | | ÁøÆø È®µµ ¡¾0.3%, À§»ó È®µµ¡¾0.1ÀÇ °íÁ¤È®µµ ±¸Çö | | | ȯ°æ ½ÃÇè¿¡µµ ÀûÇÕÇÑ -40¡É ~ +85¡É±îÁöÀÇ ³ÐÀº »ç¿ë ¿Âµµ ¹üÀ§ | | | DC ~ 20kHzÀÇ ³ÐÀº ÁÖÆļö ´ë¿ª | | | ÇѼÕÀ¸·Î Á¶ÀÛÀÌ °¡´É ¼ÒÇü »çÀÌÁî, Áøµ¿¿¡ °ÇÑ lock ±â´É žÀç | | | µµÃ¼ À§»ó, ±ÙÁ¢ µµÃ¼, ÀÚ±âÀåÀÇ ¿µÇâÀ» ±âÁ¸Ç° ´ëºñ °æ°¨ | | | ÀÚµ¿Â÷ ¹èÅ͸®ÀÇ ¼öÁö ÃøÁ¤, ÀιöÅÍ º¯È¯ È¿À² Æò°¡ µî¿¡ È°¿ë | | | [´ÜÀÚ Çüź° ¸ðµ¨ ±¸ºÐ] | | | CT6846 : AC/DC 500A | | | CT6846-05 : AC/DC 500A, 12pin ´ÜÀÚ | |
|
|
|
|
|
| Rated current | 1000A AC/DC | | Max. allowable input | 1700A DC(requires derating) | | Frequency characteristics | DC to 20 kHz Phase: DC to 20 kHz | | Amplitude and phase accuracy | DC ¡¾0.3 % rdg. ¡¾0.02 % f.s. (Phase: Not defined) DC < f ¡Â 100 Hz ¡¾0.3 % rdg. ¡¾0.01 % f.s. (Phase: ¡¾0.1 deg) Defined to 200 kHz | | Power consumption | 7.5 VA max. (at 500 A/55 Hz, ¡¾12 V power requirement) | | Output voltage | 2 mV/A (voltage output with the Sensor Unit 9555-10, use with a device having a 1 M¥Ø input resistance or higher) | | Core diameter | ¥õ 50 mm (1.79 in) | | Operating temperature, humidity | -40 ¡ÆC to +85 ¡ÆC (-40 ¡ÆF to 185 ¡ÆF), 80% rh or less (with no condensation) | | Power supply | DC ¡¾11 V to ¡¾15 V (Power suppled via the 9555-10, which supports 100 to 240 V AC) | | Dimension and Mass | 238 mm (6.02 in)W ¡¿ 116 mm (2.64 in)H ¡¿ 35 mm (0.98 in)D cord length: 3 m (9.84 ft), 990 g (34.9 oz) | | Accessories | Instruction manual ¡¿1, Mark bands ¡¿6, Carrying Case¡¿1 | | Compatible models | CT6846 Combination status | CT6846-05 Combination status | | Model 3390 | ¡â (In combination, recognized as 500A AC/DC, CT ratio needs to be set to [2]) | ¡â (In combination, recognized as 500A AC/DC, CT ratio needs to be set to [2], requires Conversion, Cable CT9901) | | Model PW6001 | ¡â (In combination, recognized as 500A AC/DC, CT ratio needs to be set to [2], requires Conversion, Cable CT9900) | OK | | Input unit 9602 for 3193-10/ 3193/ 3194 | ¡â (In combination, recognized as 500A AC/DC, CT ratio needs to be set to [2]) | ¡â (In combination, recognized as 500A AC/DC, CT ratio needs to be set to [2], requires Conversion Cable CT9901) | | Model 8971 for the MR8847-01s | ¡â (In combination, recognized as 9279 [500 A rated], requires Conversion Cable 9318) Maximum number of connectable sensors when using MR8827 or MR8847-51/52/53: 5 | ¡â (In combination, recognized as 9279 [500 A rated], CT ratio needs to be set to [2], requires Conversion Cable 9318 & CT9901) Maximum number of connectable sensors when using MR8827 or MR8847-51/52/53: 5 | | Model 8940 for the Memory Hicorders | ¡â (In combination, recognized as 500A AC/DC, CT ratio needs to be set to [2], requires Conversion, Cable 9705 & 9318) Maximum number of connectable sensors when using 8860-50 or 8860-51: 8 | ¡â (In combination, recognized as 500A AC/DC, CT ratio needs to be set to [2], requires Conversion, Cable 9705, 9318 and CT9901) Cable 9705, 9318 and CT9901) 8860-50 or 8860-51: 8 | | |
|
|
|
|
|
|
|
|