±¸¸Å ¹× ±â¼úÁö¿ø ¹®ÀÇ
02-2273-1892
We use ABCpdf for all our PDF generation
HOME > Á¦Ç° °Ë»ö > CT6845
    
 
CT6845   AC/DC CURRENT PROBE
"±¤´ë¿ª・°íÁ¤È®µµ ÃøÁ¤, ºÐÇÒÀü·ù¼¾¼­ 500A"
 
       
 
ÁøÆø È®µµ ¡¾0.3%, À§»ó È®µµ¡¾0.1ÀÇ °íÁ¤È®µµ ±¸Çö
ȯ°æ ½ÃÇè¿¡µµ ÀûÇÕÇÑ -40¡É ~ +85¡É±îÁöÀÇ ³ÐÀº »ç¿ë ¿Âµµ ¹üÀ§
DC ~ 200kHzÀÇ ³ÐÀº ÁÖÆļö ´ë¿ª
±½Àº ÄÉÀ̺íÀ̳ª ´õºí ¹è¼±µµ ÃøÁ¤ °¡´ÉÇÑ ´ë±¸°æ Ŭ·¥ÇÁ ŸÀÔ
µµÃ¼ À§»ó, ±ÙÁ¢ µµÃ¼, ÀÚ±âÀåÀÇ ¿µÇâÀ» ±âÁ¸Ç° ´ëºñ °æ°¨
ÀÚµ¿Â÷ ¹èÅ͸®ÀÇ ¼öÁö ÃøÁ¤, ÀιöÅÍ º¯È¯ È¿À² Æò°¡ µî¿¡ È°¿ë
 
[´ÜÀÚ Çüź° ¸ðµ¨ ±¸ºÐ]
CT6845 : AC/DC 500A
CT6845-05 : AC/DC 500A, 12pin ´ÜÀÚ
 

  Rated current 500A AC/DC
  Max. allowable input 1000A DC(requires derating)
  Frequency
characteristics
DC to 100 kHz
Phase: DC to 100 kHz
  Amplitude and
phase accuracy
DC ¡¾0.3 % rdg. ¡¾0.02 % f.s. (Phase: Not defined)
DC < f ¡Â 100 Hz ¡¾0.3 % rdg. ¡¾0.01 % f.s. (Phase: ¡¾0.1 deg)
Defined to 200 kHz
  Power consumption 7 VA max. (at 500 A/55 Hz, ¡¾12 V power requirement)
  Output voltage 4 mV/A (voltage output with the Sensor Unit 9555-10, use with a device having
a 1 M¥Ø input resistance or higher)
  Core diameter ¥õ 50 mm (1.79 in)
  Operating temperature, humidity -40 ¡ÆC to +85 ¡ÆC (-40 ¡ÆF to 185 ¡ÆF), 80% rh or less (with no condensation)
  Power supply DC ¡¾11 V to ¡¾15 V (Power suppled via the 9555-10, which supports 100 to 240 V AC)
  Dimension and Mass 238 mm (9.37 in)W ¡¿ 116 mm (4.57 in)H ¡¿ 25 mm (1.38 in)D
cord length: 3 m (9.84 ft), 870 g (30.7 oz)
  Accessories Instruction manual ¡¿1, Mark bands ¡¿6, Carrying Case¡¿1

  Compatible models CT6845 Combination status CT6845-05 Combination status
  Model 3390 OK ¡â(Requires Conversion Cable CT9901)
  Model PW6001 ¡â (Requires Conversion Cable CT9900) OK
  Input unit 9602 for 3193-10/ 3193/ 3194 OK (In combination, recognized as 500A AC/DC) ¡â (In combination, recognized as 500A AC/DC, requires Conversion Cable CT9901)
  Model 8971 for the MR8847-01s ¡â (In combination, recognized as 9279 [500 A rated], requires Conversion Cable 9318)
Maximum number of connectable sensors
when using MR8827 or MR8847-51/52/53: 5
¡â (In combination, recognized as 9279 [500 A rated], requires Conversion Cable 9318 & CT9901)
Maximum number of connectable sensors
when using MR8827 or MR8847-51/52/53: 5
  Model 8940 for the Memory Hicorders ¡â (In combination, recognized as 500A AC/DC, requires Conversion Cable 9705 and 9318) ¡â (Requires Conversion Cable 9705, 9318 and CT9901)


Options

SENSOR UNIT
9555-10


CONNECTION CORD
9165


CONNECTION CORD(BNC-BNC)
L9217


¿¬Àå ÄÉÀ̺í
9706


CONVERSION CABLE
CT9900


CONVERSION CABLE
CT9901


EXTENSION CABLE
CT9902


º¯È¯ ÄÉÀ̺í
9705


CONVERSION CABLE
9318

CT6845 Ä«´Þ·Î±× ´Ù¿î·Îµå